Image

    Z955W

    Wireless Zoning Master Control 
    Up to 2 Heat, 2 Cool Conventional 
    Up to 3 Heat, 2 Cool Heat Pump 
    Battery or Hardwire

    7 Day, 5/1/1 or Non-Programmable

    Simple. Affordable. Professional.

    Image
    table.GeneratedTable { width: 100%; background-color: #ffffff; border-collapse: collapse; border-width: 2px; border-color: #ffffff; border-style: dotted; color: #000000; } table.GeneratedTable td, table.GeneratedTable th { border-width: 2px; border-color: #ffffff; border-style: dotted; padding: 3px; } table.GeneratedTable thead { background-color: #ffffff; }
    The display range of temperature 41˚F to 95˚F (5˚C to 35˚C)
    The control temperature range 44˚F to 90˚F (7˚C to 32˚C)
    Load rating 1 amp per terminal, 1.5 amp maximum all terminals combined
    Display accuracy ± 1 °F
    Swing (cycle rate or differential) Heating is adjustable from 0.2°F to 2.0°F - Cooling is adjustable from 0.2°F to 2.0°F
    Power source 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire)
    Battery power from 2 AA Alkaline Energizer batteries
    Operating ambient 32° to +105° (O° to + 41°C)
    Operating humidity 90% non-condensing maximum
    Dimensions of thermostat 4.7"W x 4.4"H x 1.1"D

     Z955W

     

    Z955W Zoning Thermostat • Easy wireless zoning installations
    • Wireless thermostat, equipment module and damper module.
    • Control any zone from master control
    • Set dual fuel balance points (requires RZ250W)
    • Up to 5 zones. (requires additional RZ251W, Z260W)
    • Connect to discharge air sensor • Touchscreen
    • Easy menu driven programming
    • 13 sq. inch display with blue back-light
    • Programmable fan
    • Separate heating and cooling swing (cycle rate) adjustments
    • Adjustable set-point limits
    • Constant on Display Light
    • Keypad lockout
    • 5 minute compressor delay
    • Filter change indicator
    • Simple private label badge system
    • Easy wire color coded terminal blocks
    • Universal sub-base
    • 5 year warranty
    • Programmable
    • Keypad lockout                                           

    RZ251W

     

    • Secondary zoning control (Z955W required and sold separately)
    • Wireless Sensor on single zone system (T955WH required)
    • 3 mounting options: desktop, removable wall mount, permanent wall mount sensor only
    • Configurable for ambient sensor only or sensor, set point and system keys.*
    • Connect up to 4 indoor remotes to a T955WH or Z955W
    • Battery powered

    Z260W

     

    Z260W

     

    • Wireless control zoning damper
    • For use with Z955W (master zoning control or RZ251W (Secondary zone control)
    • Compatible with 24VAC power open, power closed, and power open and power closed damper types.         

    ZDA250W

     

    • Measures discharge air temperature for safe and efficient zone control (or zoning)
    • Set high and low limits in the duct for zoning applications to protect equipment
    • Requires Z955W
    • Mount in the duct above heat exchanger
    • 24VAC hardwire

    RZ250W

     

     

    • Wireless Outdoor Remote Sensor
    • Accessory for T955WH and Z955W (required and sold separately)
    • Displays outdoor temperature on T955WH and Z955W
    • User selectable balance point
    • Wireless balance point for heat pumps
    • Weatherproof case
    • Battery powered

    Z955W


    Z955W Installation Manual

    Z955W Operation Manual

    RZ251W


    RZ251W Installation Manual

    RZ251W Operation Manual

    Z260W


    RZ251W Installation Manual

    ZDA250W


    ZDA250W Installation Manual

    RZ250W


    RZ250W Installation Manual

    Z955W Submital Sheet




    Pro1 Linecard

    Pro1 Line Card
    © 2019 Pro1iaq. All Rights Reserved.